Officiell sammanfattning · English
Vad upphandlas?
The system must be a benchtop instrument able to measure particles concentration and size profile in biological and other liquid samples as small as 200 nm without additional processing (i.e. operate using the coulter principle or equivalent and be able to measure large protein aggregates, blood platelets and characterise mammalian cells or spheroids without the need of using nucleus staining). It must deliver accurate, reproducible size and concentration measurements across 0.2–1,600 μm in samples of 10-2000 µL, support volumetric flow mode, data reprocessing and ISO 9276-1 reporting. The instrument must feature user-friendly software, mercury-free metering, robust quality control, and be EU Annex 11 of the Good Manufacturing Practice (GMP) Guideline compliant and or FDA 21 CFR Part 11 co
Vägledande maskinöversättning. Den officiella sammanfattningen gäller.
Officiell sammanfattning · English
The system must be a benchtop instrument able to measure particles concentration and size profile in biological and other liquid samples as small as 200 nm without additional processing (i.e. operate using the coulter principle or equivalent and be able to measure large protein aggregates, blood platelets and characterise mammalian cells or spheroids without the need of using nucleus staining). It must deliver accurate, reproducible size and concentration measurements across 0.2–1,600 μm in samples of 10-2000 µL, support volumetric flow mode, data reprocessing and ISO 9276-1 reporting. The instrument must feature user-friendly software, mercury-free metering, robust quality control, and be EU Annex 11 of the Good Manufacturing Practice (GMP) Guideline compliant and or FDA 21 CFR Part 11 co
Gratis
Få nästa upphandlingar inom denna bransch
Få ett veckovis mejl med nya meddelanden som matchar dina kriterier. Kontrollera eller justera kriterierna innan du aktiverar din kostnadsfria bevakning.
Meddelandehistorik
Tidslinje för upphandlingsförfarandet
Följ de viktigaste stegen och uppdateringarna som är kopplade till det här upphandlingsförfarandet.
Inget annat relaterat meddelande har ännu identifierats.
Uppgifterna har strukturerats om för att bli lättare att läsa. Det officiella meddelandet och upphandlingsdokumenten gäller alltid.
Källa och tillförlitlighet
TED · 600505-2026. Kontrollerad 4 sep. 2026 06:05.
Uppgifterna har strukturerats om för att bli lättare att läsa. Det officiella meddelandet och upphandlingsdokumenten gäller alltid.