One V-Cradle scanner and one fully automatic or robotic scanner will be procured for the National Library's Mikkeli unit. Additional procurement options: - Maintenance contract as an option. - Possibility to purchase a third device, which can be either a V-Cradle scanner or an automatic / robotic scanner, purchase option within 1–2 years.
Sintesi ufficiale · English
One V-Cradle scanner and one fully automatic or robotic scanner will be procured for the National Library's Mikkeli unit. Additional procurement options: - Maintenance contract as an option. - Possibility to purchase a third device, which can be either a V-Cradle scanner or an automatic / robotic scanner, purchase option within 1–2 years.
Scadenza
5 nov 2026 10:00 UTC
Valore stimato
115.000 EUR
ApertoTEDFIN
Finlandia · Apparecchiature di laboratorio, ottiche e di precisione
Detailed engineering, manufacturing, delivery, installation, testing and commissioning of a 100 kWth circulating fluidized bed (CFB) pilot plant and an attached heat recovery steam generator (HRSG). The CFB shall be capable of combustion, gasification and other reaction modes using different feedstocks and the process gases specified in the technical documentation. The HRSG, located downstream of the CFB, shall operate as a once-through unit for steam…
Sintesi ufficiale · English
Detailed engineering, manufacturing, delivery, installation, testing and commissioning of a 100 kWth circulating fluidized bed (CFB) pilot plant and an attached heat recovery steam generator (HRSG). The CFB shall be capable of combustion, gasification and other reaction modes using different feedstocks and the process gases specified in the technical documentation. The HRSG, located downstream of the CFB, shall operate as a once-through unit for steam…
A magnetically shielded room (passive / DC shielding) for conducting paleomagnetic and rock-magnetic experiments in an ultra-low magnetic field environment will be installed within the Solid Earth Geophysics (SEG-BK102) Laboratory, Department of Geosciences and Geography, University of Helsinki, located in the Physicum building. The shielded room will contain a horizontal 2G cryogenic magnetometer (SRM) with its associated electronics, one large-volume…
Sintesi ufficiale · English
A magnetically shielded room (passive / DC shielding) for conducting paleomagnetic and rock-magnetic experiments in an ultra-low magnetic field environment will be installed within the Solid Earth Geophysics (SEG-BK102) Laboratory, Department of Geosciences and Geography, University of Helsinki, located in the Physicum building. The shielded room will contain a horizontal 2G cryogenic magnetometer (SRM) with its associated electronics, one large-volume…
Con il tuo consenso, Google ci aiuta a capire come viene usato Tenderiva e a misurare la nostra pubblicità. Puoi scegliere solo le statistiche. Nessuna pubblicità personalizzata o attività di remarketing.