One V-Cradle scanner and one fully automatic or robotic scanner will be procured for the National Library's Mikkeli unit. Additional procurement options: - Maintenance contract as an option. - Possibility to purchase a third device, which can be either a V-Cradle scanner or an automatic / robotic scanner, purchase option within 1–2 years.
Službeni sažetak · English
One V-Cradle scanner and one fully automatic or robotic scanner will be procured for the National Library's Mikkeli unit. Additional procurement options: - Maintenance contract as an option. - Possibility to purchase a third device, which can be either a V-Cradle scanner or an automatic / robotic scanner, purchase option within 1–2 years.
Rok
5. stu 2026. 10:00 UTC
Procijenjena vrijednost
115 000 EUR
OtvorenoTEDFIN
Finska · Laboratorijska, optička i precizna oprema
Detailed engineering, manufacturing, delivery, installation, testing and commissioning of a 100 kWth circulating fluidized bed (CFB) pilot plant and an attached heat recovery steam generator (HRSG). The CFB shall be capable of combustion, gasification and other reaction modes using different feedstocks and the process gases specified in the technical documentation. The HRSG, located downstream of the CFB, shall operate as a once-through unit for steam…
Službeni sažetak · English
Detailed engineering, manufacturing, delivery, installation, testing and commissioning of a 100 kWth circulating fluidized bed (CFB) pilot plant and an attached heat recovery steam generator (HRSG). The CFB shall be capable of combustion, gasification and other reaction modes using different feedstocks and the process gases specified in the technical documentation. The HRSG, located downstream of the CFB, shall operate as a once-through unit for steam…
A magnetically shielded room (passive / DC shielding) for conducting paleomagnetic and rock-magnetic experiments in an ultra-low magnetic field environment will be installed within the Solid Earth Geophysics (SEG-BK102) Laboratory, Department of Geosciences and Geography, University of Helsinki, located in the Physicum building. The shielded room will contain a horizontal 2G cryogenic magnetometer (SRM) with its associated electronics, one large-volume…
Službeni sažetak · English
A magnetically shielded room (passive / DC shielding) for conducting paleomagnetic and rock-magnetic experiments in an ultra-low magnetic field environment will be installed within the Solid Earth Geophysics (SEG-BK102) Laboratory, Department of Geosciences and Geography, University of Helsinki, located in the Physicum building. The shielded room will contain a horizontal 2G cryogenic magnetometer (SRM) with its associated electronics, one large-volume…
Uz vaš pristanak Google nam pomaže razumjeti korištenje Tenderiva i mjeriti učinkovitost naših oglasa. Možete odabrati samo statistiku. Bez personaliziranih oglasa i ponovnog marketinga.